Search or filter tech tips on title keywords or instrument. Don't find what you're looking for? Some older documents may not be included in this table. Use the site search to search all documentation for current and discontinued instruments.

Summary
Changing metadata after it has been collected This tech tip describes how to change incorrect or incomplete metadata in EddyPro. EddyPro, LI-7500A/RS, LI-7500DS, LI-7200/RS
The Power of FV2200 Tech tip that describes some powerful features of FV2200 software for evaluating leaf area index data collected from the LAI-2200C. LAI-2200C
A Solution for LI-180 Extended Power For powering the LI-180 while logging continuously, an AC power supply is required. This tech tip describes one solution using a rechargable AC power supply. LI-180
Manual logging with the LI-180 Spectrometer This tech tip shows how to log and download data from the LI-180 LI-180
Configuring automatic data logging and computing the Daily Light Integral (DLI) This tech tip describes how to configure the LI-180 to log data, and then how to compute the daily light integral from the data. LI-180
Logging Ratios of Spectral Bands The LI-180 can compute spectral ratios from measured data. This tech tip describes how to set it up. LI-180
Downloading data from the LI-180 Simple instructions for copying data from the LI-180 to a personal computer. LI-180
Updating the LI-180 Firmware Instructions for installing updated firmware on the LI-180 Spectrometer. LI-180
Amplifying the Output Signal from LI-COR Radiation Sensors Technical tip describing how to amplify the signal from LI-COR radiation sensors for use with other manufacturer's data logging devices. LI-190R, LI-191R, LI-192, LI-193, LI-200R, LI-210R
Connecting LI-COR light sensors to voltage-reading data loggers Tech tip that describes how to connect a light sensor to a voltage reader or datalogger. LI-190R, LI-191R, LI-192, LI-193, LI-200R, LI-210R
Measuring PPFD and PPFFR with the LI-192 and LI-193 Underwater Light Sensors Tips for measuring PPFD and PPFDR underwater using the LI-192 and LI-193 Underwater Quantum Sensors LI-192, LI-193
Dimensional Drawing for Mounting the LI-192 Underwater Quantum Sensor This technical tip provides dimensional drawings that can be used to mount the LI-192 Underwater Quantum Sensor to a user-supplied mounting fixture. LI-192
A Quick and Easy Way to Merge LI-1500 Light Sensor Logger Files This technical tip describes how to merge LI-1500 Light Sensor Logger files using the fv7x00 File Viewer program. LI-1500
Re-seating the SD card in the LI-1500 and LAI-2200C Video showing how to reinstall the SD card in the LI-1500 and LAI-2200C. LI-1500, LAI-2200C
Adjusting and Replacing the LI-3050C Transparent Belt Conveyer Accessory This technical tip describes how to replace and/or make adjustments to the belt on the LI-3050C Transparent Belt Conveyor Accessory. LI-3000C
Hints to Minimize Data Accumulation with the LI-3050C Belt Accessory Advice to reduce spurious counts. LI-3000C
Correcting Continuous Data Accumulation with the LI-3000C Advice on correcting spurious counts. LI-3000C
Tips for the LI-3100C Lamp Technical tip describing how to prepare the fluorescent lamp in the LI-3100 series Area Meters. LI-3100C
Correcting Continuous Area Accumulation with the LI-3100C Technical tip that describes how to troubleshoot the situation whereby area accumulates continuously on the LI-3100C Leaf Area Meter. LI-3100C
Selecting the Power Supply Frequency Main power supplies differ around the world, but the LI-3100C is compatible with all of them. This tech tip describes how to change the power supply setting. LI-3100C
Using the Perforated Calibration Plate Instructions for using the new perforated calibration plate with the LI-3100C Area Meter. LI-3100C
Downloading Data Using a Serial Connection This document describes how to download data from the LI-6400/XT using serial a connection. LI-6400/XT
LI-6400/XT Shipping Recommendations This tech tip describes how to package the LI-6400/XT for shipping. LI-6400/XT
Look Ma, No Wires! Wireless Connectivity and the LI-6400XT This technical tip describes how to incorporate wireless network connectivity into the LI-6400/XT, using a wireless router. LI-6400/XT
Faster Field Measurements of Asat With the LI-6400XT Portable Photosynthesis System This technical tip describes how to make faster field measurements of the light-saturated rate of net CO2 fixation under ambient conditions (Asat) with the LI-6400/XT. LI-6400/XT
Dealing with Large, Moist Samples This technical tip describes how to deal with high humidities when measuring large, moist samples in the Bryophyte and/or Conifer chambers on the LI-6400/XT. LI-6400/XT
When Ambient H2O is not Leaf Chamber H2O This technical tip describes how to maintain the proper relative humidity in the LI-6400/XT leaf chamber to allow the plant to compensate for the loss of humidity due to removal of the boundary layer. LI-6400/XT
‘Drieing’ Your Drierite the ‘Rite’ Way This technical tip describes how to regenerate Drierite after it has been exhausted, for re-use with the scrubber tubes on the LI-6400/XT or other gas analyzers. LI-6400/XT
Setting the Proper Height of the 6400-04 Thermocouple This technical tip describes the proper positioning of the 6400-04 leaf temperature thermocouple in relation to the leaf chamber, for the LI-6400/XT Portable Photosynthesis System. LI-6400/XT
Connecting a Soil Moisture Probe to the LI-6400XT This technical tip describes how to connect a Decagon EC-5 soil moisture probe to the LI-6400/XT Portable Photosynthesis System. LI-6400/XT
Reclaiming storage space If the file system gets too full, you may have trouble working with files. This tip presents some solutions to the problem. LI-6400/XT
A Sticky Solution for a Tricky Problem This tech tip describes how to align small blades of grass or needles and keep them in place in the LI-6400/XT standard leaf chamber. LI-6400/XT
Making One-Sided Leaf Measurements This tip describes how to make measurements from one side of a leaf. LI-6400/XT
Measuring Photorespiration with the LI-6400/XT This tip describes some important considerations for measuring photorespiration using the LI-6400/XT. LI-6400/XT
Recomputing LI-6400/XT data sets generated with older software versions How to recompute measurements collected with older software versions LI-6400/XT
Where's My Serial Port? This note describes how to use a serial-to-USB adapter with instruments that required a RS-232 port. LI-6400/XT, LI-7500A/RS, LI-7200/RS, LI-7700, LI-8100/A
Ten Facts About the LI-6020 Battery Charger Information about the four-port battery charger. LI-6400/XT, LI-8100/A
Making an Instrument Toolkit A toolkit will help you be prepared for nearly any situation. LI-6400/XT, LI-6800
Using CO2 and H2O Scrubbers with LI-COR Gas Analyzers This note describes the internal chemical scrubbers that keep absorbing gases out of internal spaces in the optical bench. LI-6400/XT, LI-6800, LI-7500DS, LI-7500A/RS, LI-7200/RS, LI-7700
Resources and software for photosynthesis data analysis Describes software and literature for fitting the Farquhar, von Caemmerer and Berry (FvCB) model of photosynthesis (Farquhar, von Caemmerer & Berry 1980). LI-6400/XT, LI-6800
CO2 Cartridges for the LI-6400/XT and LI-6800 This technical tip describes the best CO2 cartridges to use and provides some tips for their use. LI-6400/XT, LI-6800
Shipping lithium-ion batteries Suggestions for storing and shipping lithium-ion batteries used with many LI-COR products. LI-6800, LI-7810, LI-7815, LI-7820, LI-7825, Smart Chamber
Sending emails from the LI-6800 The LI-6800 can be configured to automatically email data files directly to a Gmail™ account using a background program. This tech tip tells how. LI-6800
Going on a remote field trip? What would a LI-COR scientist bring? We're often asked what a LI-COR scientist would take when preparing for field work. This tech tip answers the question and lists some things to consider when preparing for your own field work. LI-6800
Controlling the LI-6800 via Remote Access for Training and Demonstration Tech tip that describes how to connect to the LI-6800 using a VNC application, so you can control the instrument from a computer or mobile device. LI-6800
Shipping Recommendations Wondering what to pack? How to fit it all into the case? This describes how to pack your LI-6800 for shipping. LI-6800
Gassing up your LI-6800: How to connect your own gas supply Tech tip that shows two ways to connect tank air to the LI-6800. LI-6800

Leaf Temperature Thermocouple Height

Tech tip that shows a quick way to set the leaf temperature thermocouple height correctly every time.

LI-6800
Resolving leaks with the LI-6800 This tech tip will help you identify and solve leaks when using the LI-6800. LI-6800
Upgrading the Wheels on the LI-6800 Travel Case This tech tip describes how to upgrade the wheels of your LI-6800 carrying case. LI-6800
CO2 Cartridges for the LI-6400/XT and LI-6800 This technical tip describes the best CO2 cartridges to use and provides some tips for their use. LI-6800, LI-6400/XT
Building a Large Prompt List This tech tip shows how to customize a prompt list in a text editor. LI-6800
LI-7000 USB Connection Issue on Windows 8 This technical tip describes how to fix a problem whereby the USB port does not function with the LI-7000 on computers using Windows 8. LI-7000
Constructing a Water Trap For the 7200-101 or 7200-102 Flow Module Instructions for installing a water trap between the gas analyzer and flow module. LI-7200/RS
Reducing High Frequency Noise from the 7200-101 or 7200-102 Flow Module Tech tip that shows a simple way to install a muffler on the 7200-101 outlet to reduce high-frequency noise. LI-7200/RS
Testing instrument cables Video showing how to test a cable using a multi-meter. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8100/A, LI-8250
Troubleshooting Ethernet Connectivity Issues with LI-COR Gas Analyzers Suggestions for solving network issues. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8250
An Often-Overlooked Constraint to Powering Instruments: Voltage Drop Long cables can cause a voltage drop. This tip describes the problem and offers some solutions. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8100/A, LI-8250
Using a Cradlepoint Modem with LI-COR Instrument Systems Guidance for using a Cradlepoint Modem with remote eddy covariance systems. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8250
Cellular Communication for EC Stations Guidance for cellular communication with a user-supplied radio. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700
Dealing with Daylight Saving Time This technical tip advises against the use of daylight saving time when setting instrument clocks LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-8250, LI-8100A, Smart Chamber, LI-7700, LI-7810, LI-7815, LI-7825
Uploading data files to Dropbox Instructions for configuring Dropbox® and LI-COR eddy covariance systems (win-GHG software) or the LI-8250 Multiplexer to automatically transfer data on schedule. LI-7200/RS, LI-7500DS, LI-7500A/RS, LI-7700, LI-8250
Converting a CH4-enabled LI-7550 to Measure CO2 Tech tip that describes how to update the software in LI-7700-enabled LI-7550 AIU so it is compatible with an LI-7200/RS or LI-7500A/RS. LI-7200/RS, LI-7500A/RS, LI-7700
Why Does the AGC Signal Change After Cleaning the Optical Cell? This technical tip describes why the AGC (or signal strength) values may deteriorate after cleaning the optical cell, and how to avoid exposing the detector to UV light. LI-7200/RS, LI-7500A/RS
Interpreting Diagnostic Values This technical tip describes how to interpret the diagnostic bit values that are output by the LI-7200 and LI-7500A CO2/H2O Analyzers. LI-7200/RS, LI-7500A/RS
Logging Analog Data from the CSAT3 in EC Datasets Tech tip describes how to configure the Campbell Scientific CSAT3 sonic anemometer to log raw flux data into the .ghg file format for use with the LI-7500A/RS, LI-7200/RS. LI-7500A/RS, LI-7200/RS
Logging Analog Data from an RM Young Sonic Anemometer in EC Datasets Tech tip describes how to connect analog outputs from an RM Young anemometer to a LI-COR eddy covariance system. LI-7500A/RS, LI-7200/RS
How to Routinely Check an Eddy Covariance System to Ensure Normal Operation Tech tip that describes some practices that will keep your EC station up and running. LI-7500A/RS, LI-7200/RS
Monitoring and downloading data from a remote Trace Gas Analyzer An overview of settings used to remotely monitor and download data from a Trace Gas Analyzer LI-7810, LI-7815, LI-7820, LI-7825
Troubleshooting RS-232 Connectivity Issues Tech Tip describing how to troubleshoot RS-232 connection issues. LI-820, LI-840A, LI-8100A
Air Pumps and Accessories for LI-COR Gas Analyzers Suggested parts and vendors for air pumps and other accessories needed to flush the sample cells of many LI-COR closed-path gas analyzers. LI-820, LI-840A, LI-830, LI-850, LI-7000
Temporary Fix for a Bad IR Source These tips might allow you to get a bit more data from an analyzer. LI-820, LI-840/A, LI-830, LI-850, LI-870, LI-8100/A
Replacing the Source and Detector in the LI-8x0 Analyzers and LI-8100/A Instructions for replacing the optical source and detectors. LI-820, LI-840/A, LI-830, LI-850, LI-870, LI-8100/A
Terrible, Horrible, No Good, Very Bad Data Four reasons for bad or questionable data, along with solutions. LI-820, LI-840/A, LI-830, LI-850, LI-870, LI-8100/A
Making soil collars for the LI-8250, Smart Chamber, and other soil chambers Learn how to make your own soil collar for current and legacy soil gas flux systems with this tech tip. LI-8100A, LI-8250, Smart Chamber, LI-6400/XT, LI-6800

More documents for discontinued products